OPEN COM

From QB64 Wiki
Jump to navigation Jump to search

The OPEN COM statement is used to access a computer's serial port COM.


Syntax

OPEN "COMn: Speed, Parity, Bits, Stopbit, [Options]" [FOR {RANDOM|BINARY|OUTPUT|INPUT}] AS #P [LEN = byteSize]


Parameters

  • Speed (baud rate): 50, 150, 300, 600, 1200, 1800, 2400, 9600 (QBasic's maximum), 19200 or 115200 (QB64's maximum).
  • Parity: N (none), E (even), O (odd), S (space) or M (mark). Note: If 8 bits, use parity N for numerical data.
  • Bits = number of bits/byte: Valid numbers: 5, 6, 7 or 8
  • Stopbit = number of stop bits: Valid numbers: 1, 1.5 or 2
  • Optional COM port Options (separated by commas):
  • ASC : ASCII byte mode. End of line = CHR$(13). End of file = CHR$(26)
  • BIN : Binary byte mode. Default mode if ASC is not used(option not required).
Below ms is the timeout in milliseconds 1 to 65535. Zero ignores a timeout. Default without ms = 1000 :
  • CD[ms] : Time until timeout of DCD (Carrier Detect) line in. CD0 ignores timeouts.
  • CS[ms] : Time until timeout of CTS (Clear to Send) line in. CS0 ignores timeouts.
  • DS[ms] : Time until timeout of DSR (Data Set Ready) line in. DS0 ignores timeouts.
  • OP[ms] : Time until data lines become active. If timeout then OPEN fails, OP0 ignores timeouts.
  • RB[b] : Size of receive buffer in bytes when used. Default when not used = 512 bytes
  • TB[b] : Size of transmit buffer in bytes when used. Default when not used = 512 bytes
  • RS : Supress detection of Request to Send (RTS) line.


Description

  • If any optional CD, CS, DS or OP timeouts occur the OPEN will fail or port access will stop. Try 0 to ignore.
  • QB64 can open any COMn port number from 1 to 9.
  • See Windows System Device Manager for COM port numbers and port addresses &H3F8, &H2F8, &H3E8 and &H2E8.
  • Four commas are required after the Speed, Parity, Bits, and Stopbit, even if none of the Options are used.
  • Other OPEN options are optional and in any order separated by commas within the OPEN command string.(See list below)
  • The optional FOR access mode can be OUTPUT, INPUT or RANDOM (default mode when no FOR statement is used).
  • Currently, QB64 only supports OPEN FOR RANDOM access using the GET/PUT commands in BIN mode.
  • Use the BIN option listed below for BINARY byte mode port access.
  • The LEN statement is also optional. The default record size is 512 bytes when not used.
  • Use the LOC(portnumber) function to determine that there is data in the receive buffer when the value is greater than 0.
  • OPEN AS number can use a FREEFILE value. Numbers used by files already open cannot be used by OPEN COM.
  • Keyword Not Supported in Linux or MAC versions


Examples

Example 1: Checking to see if a COM port exists. If the port does not exist QBasic will cause a Windows access error.

ON ERROR GOTO Handler FF = FREEFILE comPort$ = "COM1:" 'try a COM port number that does not exist CONST comMode$ = "9600,N,8,1,CS0,DS0" 'Use 0 to avoid timeouts OPEN comPort$ + comMode$ FOR RANDOM AS FF IF errnum = 0 THEN PRINT "COM exists! K$ = INPUT$(1) END Handler: errnum = ERR PRINT "Error:"; errnum RESUME NEXT

Explanation: QB64 may create error 68 if COM is not found. Use a zero CD, CS, DS or OP timeout value to avoid COM timeouts.


Example 2: Opening a COM port with the BIN, CS0 and DS0 options in QB64.

DIM bytestr AS STRING * 1 'one byte transfers INPUT "COM port number #", port$ 'any COM port number available OPEN "COM" + port$ + ":9600,N,8,1,BIN,CS0,DS0" FOR RANDOM AS #1 DO 'main loop 'receive data in buffer when LOC > 0 IF LOC(1) THEN GET #1, , bytestr PRINT "[" + bytestr + "]"; END IF 'transmit (send) k$ = INKEY$ IF LEN(k$) = 1 THEN k = ASC(k$) IF k >= 32 THEN 'ignore control key codes PRINT ">" + k$ + "<"; bytestr = k$: PUT #1, , bytestr END IF END IF LOOP UNTIL k$ = CHR$(27) CLOSE #1: PRINT "Finished!"


Example 3: Sending string data from one COM port to another requires predefined length strings:

DIM SHARED ByteIn AS STRING * 1 'One byte transfers DIM SHARED Byte4 AS STRING * 4 'Four byte transfers Byte4 = CHR$(254) + CHR$(175) + CHR$(0) + CHR$(3) 'Command code to query all 4 banks of switch input board. OPEN "COM1:115200,N,8,1,BIN,CS0,DS0" FOR RANDOM AS #1 'Open port used to send commands. OPEN "COM2:115200,N,8,1,BIN,CS0,DS0" FOR RANDOM AS #2 'Open port used to receive commands. PUT #1, , Byte4 'Send the 4 byte command. Start# = TIMER DO UNTIL LOC(2) <> 0 'Check if there is data received at com2 IF TIMER - Start# > .5 THEN EXIT DO 'Exit loop if no data arrives within .5 seconds. LOOP IF LOC(2) = 0 THEN 'If no data was received..... PRINT "No data received from COM port." END END IF PRINT "Received from COM2:"; DO UNTIL LOC(2) = 0 'Read data from COM2 until there is no more data. GET #2, , ByteIn PRINT ASC(ByteIn); LOOP END

Code courtesy of forum member Hydrofoiler


See also



Navigation:
Go to Keyword Reference - Alphabetical
Go to Keyword Reference - By usage
Go to Main WIKI Page